Air Quality Monitor System

OC-9200 Dust Monitoring Equipment

  • Urban dust monitor
  • dust online monitor
  • Dust Monitoring Equipment
  • fixed dust monitoring system
  • Product description: The OC-9200 Dust monitoring system used to detect the Particulate matter PM2.5 and PM10,TSP, Noise, Meteorological parameters (including of Temperature, Humidity, Wind speed, Wind direction, Barometri
Get A Quote
Contact Us

Description:

The OC-9200 Dust monitoring system used to detect the Particulate matter PM2.5 and

PM10,TSP, Noise, Meteorological parameters (including of Temperature, Humidity,

Wind speed, Wind direction, Barometric pressure ). Combined with industrial laser sensor

technology and unique heating dehumidification compensation device, the influence of

ambient temperature and humidity on the detection results of particulate matter is reduced.

Features:

Modular designed , easy to set different monitoring factors on demands, suitable for large

scale grid distribution points;

Calibration is carried out on site according to the traceable reference standards;

No need to change the sampling cutter, it can detect the PM10, PM2.5, TSP at the same time;

The circuit adopts industrial embedded processor, suitable for the harsh outdoor environment and the working temperature is -40~70 degree;

The particulate sampling is controlled by dynamic heating and dehumidification to remove the influence of water mist on measurement data;

Adopts long-life anti-jamming sampling power system, quiet and efficient;

the sampling period is adjusted. Adopts the industrial transmission module to ensure the stability and reliability of the data transmission;

the system with the two-channel communication to ensure the data continuity;

It can realize remote data transmission and read the system status information remotely;

Also can realize the remote control, modify instrument parameters remotely and diagnose faults;

(Optional) IP cameras with various parameters to record the video;

Real-time data displaying and the update time is adjustable;

Large size LED to display the data. Various installation modes;

The Air quality monitor station with many different applications:

Pollution control in traffic environment;

Road and tunnel pollution monitoring;

Urban air quality monitoring;

Emission monitoring of particulate and pollution sources;

Long-term air quality trends analysis;

Short-term atmospheric environmental impact assessment;

Environmental monitoring in residential areas, schools, Hospitals;

Park / forest environmental monitoring;

Industrial area air quality monitoring: Chemical plant, Power plant, Landfill, Incineration station, Port, Sewage treatment plant, Storage facilities, Underground facilities, etc.

Technical Parameter:

Items  

Description

 

Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

Particle Modules

 

 

 

 

 

Monitor method Continuously, automatically and real-time
Working principle Light scattering technique
Measurement data PM2.5, PM10, TSP
Measuring range 0~1000μg/m3 (Range can be extended)
Response time ≤60s
Resolution 1μg/m3
Accuracy

/reproducibility

> 100ug/m3, ±20%
Parallelism  < 10%
Sampling flow 1.3L/min, ±0.15
Sampling time Adjustable(Default is 5munites)
Dehumidification With the automatic dehumidification function module
Cutter Cyclone cutter
Fault alarm Real-time display the fault alarm
Power supply DC12V, AC220
 

 

Wind  Speed

 

 

Range 0~45m/s
Precision ±1m/s
Output resolution 0.1m/s
 

Wind Direction

 

 

 

 

Range 0~360°
Precision ±3°
Output resolution
 

Temperature

 

Range -30℃~50 ℃
Precision ±1℃
Output resolution 0.1℃
 

 

Humidity

 

 

Range 0~95%RH
Precision ±5%RH
Output resolution 1%RH
 

 

Air  Pressure

 

 

Range 600~1100hPa
Precision ±0.5hPa
Output resolution 1hPa
 

 

 

 

 

 

 

 

 

 

 

Noise Monitor

Performance level GB/T3785/IEC61672 , Class 1
Parameter 1sLeqTLeq, LEL1L10L50L90L99Lmax,

LmiLeq8hnEAND, SdLCpeak

 

 

Microphone

Nominal diameter:12.7mm.(Free-field frequency response)
Nominal sound pressure sensitivity: 50mV/Pa
Frequency Range 10 Hz~20 kHz
Frequency weighting A、C、Z
Time weighting F、S 、I
Measuring range (30~130) dBA、(40 ~130) dBC、(45~130) dB
Display 128×64 dot matrix liquid crystal display (LCD), Resolution: 0.1dB
Integration time The default is 10min, can be set according to needs
Repeated measurement It can be set up to 255 times, and the minimum is 1 time

If you need more details of the Air quality monitor station, welcome to contact us: