Description:
The AQM-09 Air Quality Monitoring Station can measure outdoor air pollutants in real-time, measuring data quickly and accurately. It can be customized for different applications demands, the measurement parameter can be choose from the following: the gas type Ozone(O3), Nitrogen Dioxide(NO2), Sulfur Dioxide(SO2), Carbon Monoxide(CO), Particulate matter PM2.5 and PM10, also the Noise, Meteorological parameters (including of Temperature, Humidity, Wind speed, Wind direction, Barometric pressure ), etc.
Features:
Installed with the famous brand sensor, with quick response, good linearity, stable performance and high resolution, the minimum unit up to ppb;
Designed with the all-in-one type and easy installation;
The modular design makes the later maintenance very convenient;
With the function of remote parameter correction, can save the costs;
With the built-in pump, respond quickly more than the normal diffusion sampling type;
With the Double-layer protection box, preventing it from external environment influence;
It’s with the Wireless network adapter, transmitting the data by GPRS, also with optional RS232 connection to display the data on the LED display screen;
With the Remote data acquisition system.
The Air quality monitor station with many different applications:
Pollution control in traffic environment;
Road and tunnel pollution monitoring;
Urban air quality monitoring;
Emission monitoring of particulate and pollution sources;
Long-term air quality trends analysis;
Short-term atmospheric environmental impact assessment;
Environmental monitoring in residential areas, schools, Hospitals;
Park / forest environmental monitoring;
Industrial area air quality monitoring: Chemical plant, Power plant, Landfill, Incineration station, Port, Sewage treatment plant, Storage facilities, Underground facilities, etc.
Technical Parameter:
Items | Description | Specification |
Particle Modules | Monitor method | Continuously, automatically and real-time |
Working principle | Light scattering technique | |
Measurement data | PM2.5, PM10,TSP | |
Measuring range | 0~1000ug/m3 (Range can be extended) | |
Response time | ≤60s | |
Measuring time | 0.1min (Shortest measurement time)
1min(Standard measurement time) |
|
Minimum detection limit | ≤0.001 mg/m3 | |
Instrument parallelism | ≤±10% | |
Data validity | >75% | |
Dehumidification | With the automatic dehumidification function module | |
Alarm function | With high concentration alarm function, the platform can configure the alarm threshold | |
Gas modules | Monitor method | Continuously, automatically and real-time |
Working principle | High precision Electrochemical sensor | |
Gas monitor | SO2, NO2, CO, O3 | |
Sulfur Dioxide SO2 | Measuring range: 0~2000ppb
Resolution: 1ppb Response time: <45s |
|
Nitrogen Dioxide NO2 | Measuring range: 0~2000ppb
Resolution: 1ppb Response time: <45s |
|
Ozone O3 | Measuring range: 0~2000ppb
Resolution: 5ppb Response time: <45s |
|
Carbon Monoxide CO | Measuring range: 0~200ppm
Resolution: 0.1ppm Response time: <45s |
|
Noise monitor | Measuring range: 30~130dB (A) | |
Sampling frequency: <1s | ||
Dynamic analysis range: ≥100dB (A) | ||
Frequency weighting: A, C,Z | ||
Time weighting: F, S | ||
Meteorological parameters | Temperature: Measuring range: -30℃~60℃, Precision: ±0.3℃ (20℃) | |
Humidity: Measuring range: 0~95%RH, Precision: ±5%(5%RH~95%RH, 25℃) | ||
Wind direction: Measuring range: 0~360°, Precision: ±5° | ||
Wind speed: Measuring range: 0~60m/s, Precision: ±0.3m/s | ||
Barometric pressure: Measuring range: 600~1110hpa, Precision: ±0.5hpa |
System specification:
Data efficient transmission rate | ≥95% |
Remote control | Support for remote setting |
Interface | RS485/RS232 port, Network port |
Transmission network | Automatically and real-time upload data, optional 4G/GPRS |
Box material | Q235 spray, Stainless box optional |
Scaffold material | Q235 |
Scaffold height | Standard height is 4.5m, Flange connection(1m fixed underground, 2*1.5m+1*0.5m) |
Lightning arrester | Length 1.5~2m, Q235 Galvanized material |
Working environment | Temperature: -20~50℃
Humidity: 5%RH~95%RH Pressure: 65~108Kpa |
Protection grade | IP55 |
Power supply | AC220V/50Hz/Solar power (optional) |