Fixed Toxic gas detector

OC-F08 Fixed CH4S gas detection with data storage function

  • CH4S gas detection
  • Methyl Mercaptan Gas detection
  • CE/RoHs certification
  • data storage function
  • Product description: OC-F08 Fixed gas detection used the gas sensor from the famous brands, Honeywell, CITY, Membrapor,etc. with high precision and stable quality. It can possibly connect with many controller system, such
Get A Quote
Contact Us

Description:

OC-F08 fixed CH4S gas detection used the original imported sensor and the ultra low power 32 bit microprocessor, so with the advantages of high precision, good repeatability, stable signal, respond quickly, etc. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.

Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc.


Features:
4-20mA standard analog signal and RS485 digital signal output, 200~1000HZsignal output, relay output, data restore, data logger(optional);
LED screen displaying the gas concentration, gas type, unit, instrument status etc.
Independent air chamber, the sensor is not required to replace the sensor calibration, automatic identification of key parameters of the sensor;
Protection function to prevent high gas concentration attack;

Display the gas concentration in ppm, %LEL, %vol and mg/m3 is selectable;

Infrared remote controller operation;

With the 16bit ADC acquisition chip, designed with four-layer circuit board, so with high anti-interference ability;

With the Ex-proof certificate, the Ex-proof grade is Exd II CT6.

Technical Parameter:

Detection Gas Methyl mercaptan (CH4S)
Detecting Range 0~10ppm、0~20ppm or customized
Resolution 0.001ppm, 0.01ppm
Sampling Diffusion or pump-suction, circulation selectable
Precision ≤±3%F.S
Repeatability ≤±1%
Zero drift ≤±1%(F.S/year)
Sensor Type Electrochemical sensor
Sensor Life 2~3 years
Response Time (T90) ≤20s
Alarming mode Audible-visual alarm(Optional)
Operating Environment Temperature: -30℃~60℃ (Customized for special demands)

Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter

Pressure: 86kPa~106kPa

Working Voltage 24V DC(16~30VDC)
Output Signals (Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc;

(Optional) Four-wire system RS485 digital signal output;

(Optional) Frequency signal 200~1000Hz output;

Two-level relay output:220VAC 0.5A, 5VDC 0.5A

Installation Means Wall mounted, Pipe type (Thread:M40*1.5 )
Material of Body Cast aluminum
Explosion-proof Index Ex d IIC T6
Protection Grade IP66
Electrical Interface 3/4″NPT(Female Screw)、1/2″NPT(Female Screw)
Transmit Distance ≤2000m (If more than 2000m, can add the repeater.)
Dimension 210 mm×140 mm×92 mm(L×W×H)
Weight About 1.5Kg
Standards GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010
Warranty 18months
Certificate CNEx, CE, RoHS

If any quesitons on the fixed gas detector, welcome to contact us: